Go to frontpage


Marine Boilers
& Heat Exchangers
 

Alfa Laval Aalborg OH

________________________________________________________________________________________

 

General

 

  • Oil-fired steam/hot-water boiler
  • Smoke-tube, two-pass, horizontal boiler
  • For steam or hot-water applications
  • Can be fired with marine gas oil, diesel oil or heavy fuel oil.


Design data

Hot-water capacity range:

Hot water capacity: 500-10,700 kW
Design pressure: 8 bar (g)



Aalborg OH (formerly MISSION OH) is based on technologies and long-term experience of UNEX BH/B -products. The capacity is now 750 - 16000 kg/h for steam generation. The horizontal layout minimized the space limitations in height. The low-alloyed plate material is durable against cracking for an improved lifetime. Aalborg OH boilers are normally cleaned by manual utensils. Aalborg OH can operate as a steam drum for exhaust gas economizers. If the economizer capacity is high, the size of the boiler will be increased accordingly.


Aalborg OH hot water boiler capacity, dimensions and weight

 

Thermal

capacity

Length
Diameter *)
Height

Gas

outlet

Dry

weight

Water

volume

kW

mm

mm

mm

DN

kg 

m3

500
3,140
1,340
1,540
200
2,500
1.5
750
3,285
1,585
1,785
250
3,100
2.0
1,000
3,330
1,625
1,825
300
3,600
2.5

1,700

4,095
1,710
1,910
300
4,600
3.4

2,000

4,485
1,795
1,995
400
5,200
3.9

2,700

5,450
1,925
2,125
450
6,600
5.2
3,400
5,950
2,075
2,275
500
8,100
7.1

4,000

6,160
2,135
2,335
600
9,100
7.9
5,400
6,600
2,370
2,570
600
12,800
8.5
6,700
6,900
2,600
2,800
700
16,200
13.7
8,400
7,750
2,850
3,050
700
19,900
17.2
10,700
8,150
3,150
3,350
800
25,300
21.9

 

DATA SHEET series
© Aalborg Industries 2009 (Design data are subject to change without prior notice).

 

_______________

 

Related material:

 



© Alfa Laval Aalborg A/S | Gasvaerksvej 24 | 9100 Aalborg | Denmark | Terms »