General

 

  • Oil-fired steam/hot-water boiler
  • Smoke-tube, two-pass, horizontal boiler
  • For steam or hot-water applications
  • Can be fired with marine gas oil, diesel oil or heavy fuel oil.


Design data

Steam generating capacity range:

Steam capacity: 750-16,000 kg/h
Design pressure: up to 12 bar(g)



Aalborg OH (formerly MISSION™ OH) is based on technologies and long-term experience of UNEX BH/B -products. The capacity is now 750 - 16000 kg/h for steam generation. The horizontal layout minimized the space limitations in height. The low-alloyed plate material is durable against cracking for an improved lifetime. Aalborg OH boilers are normally cleaned by manual utensils. Aalborg OH can operate as a steam drum for exhaust gas economizers. If the economizer capacity is high, the size of the boiler will be increased accordingly.


Aalborg OH steam boiler capacity, dimensions & weight

 

Steam

capacity

Length
Diameter *)
Height

Gas

outlet

Dry

weight

Water

volume

kg/h

mm

mm

mm

DN

kg 

m3

750
3,140
1,660
1,860
200
2,800
2.5
1,000
3,285
1,760
1,960
250
4,200
3.0

1,500

3,330
1,910
2,020
300
5,000
3.5

2,500

4,095
2,010
2,220
300
5,500
4.9

3,000

4,485
2,110
2,300
400
6,700
6.7
4,000
5,450
2,210
2,410
450
9,600
8.5

5,000

5,950
2,360
2,560
500
11,800
10.2
6,000
6,160
2,410
2,610
600
13,000
12.9
8,000
6,600
2,780
2,980
600
18,300
15.6
10,000
6,900
3,160
3,360
700
23,500
18.3
12,500
7,750
3,400
3,650
700
28,500
22.9
16,000
8,150
3,700
3,950
800
36,500
30.0

*) In parallel use of exhaust gas economizers, the diameter of boiler may increase.